waecE-LEARNING
Home
Technical
Mathematics
Languages
Science
Social Science
Art
Literature Arabic Islamic Studies C.R.KHistory MusicVisual Art Clothing/Textile Home Management Shorthand
 
Building Construction Paper 1, May/June. 2007  
Questions: 1 2 3 4 Main
General Comments
Weakness/Remedies
Strength
Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SPECIFICATIONS

FOUNDATION: 675 x 225 concrete strip at a depth of 1200 below ground level
FLOOR: Earth filling;
Hardcore 300
Concrete slab 150
Mortar screed 25.
WALLS: All walls are 225 sandcrete hollow blocks.
DOORS: D1 - Metal door - 1200 x 2100 x 40
D2 - Panel wooden - 900 x 2100 x 40 with 100 x 75
hardwood timber frame
D3 - Flush wooden-900 x 2100 x 40 with 100 x 75
hardwood timber frame
D4 - Flush wooden - 750 x 21OO x 40 with100 x 75
hardwood timber frame.
WINDOWS: Wl - 1800 x 1200 (3 bay)
W2 - 1200 x 1200 (2 bay)
W3 - 900 x 1200 ( 1bay)
W4 - 600 x 600 ( 1 bay).
All windows are glazed aluminium sliding type.

BEAMS/LINTEL: 225 X 225 reinforced concrete.

COLUNMS: 225 X 225 reinforced concrete

ARCHES Arch 1 - Semicircular: Height - 2700
Span - 2962.5
Arch 2• Semicircular: Height - 2700
Span - 1075.
WARDROBES: 1200 x 600
VERANDAH: Metal balustrade 900 high measured from floor level.
THRESHOLD STEPS: Rise - 150
Tread - 300
Width – 1200
ROOF: Double pitched timber roof with galvanized iron roofing sheets.
Eaves projection – 750
Pitch - 15°
Height from finished ground floor ceiling – 3000.



_____________________________________________________________________________________________________
Powered by Sidmach Technologies(Nigeria) Limited .